Amps to watts chart: 1–200 A

Watts = amps × volts, precomputed. Find your amperage in the first column and read across for the circuit voltage you have:

Current 12 V (battery, solar) 120 V (standard outlet) 240 V (large appliances)
1 A12 W120 W240 W
2 A24 W240 W480 W
3 A36 W360 W720 W
4 A48 W480 W960 W
5 A60 W600 W1,200 W
6 A72 W720 W1,440 W
7 A84 W840 W1,680 W
8 A96 W960 W1,920 W
9 A108 W1,080 W2,160 W
10 A120 W1,200 W2,400 W
11 A132 W1,320 W2,640 W
12 A144 W1,440 W2,880 W
13 A156 W1,560 W3,120 W
14 A168 W1,680 W3,360 W
15 A180 W1,800 W3,600 W
16 A192 W1,920 W3,840 W
17 A204 W2,040 W4,080 W
18 A216 W2,160 W4,320 W
19 A228 W2,280 W4,560 W
20 A240 W2,400 W4,800 W
21 A252 W2,520 W5,040 W
22 A264 W2,640 W5,280 W
23 A276 W2,760 W5,520 W
24 A288 W2,880 W5,760 W
25 A300 W3,000 W6,000 W
26 A312 W3,120 W6,240 W
27 A324 W3,240 W6,480 W
28 A336 W3,360 W6,720 W
29 A348 W3,480 W6,960 W
30 A360 W3,600 W7,200 W
35 A420 W4,200 W8,400 W
40 A480 W4,800 W9,600 W
45 A540 W5,400 W10,800 W
50 A600 W6,000 W12,000 W
60 A720 W7,200 W14,400 W
70 A840 W8,400 W16,800 W
80 A960 W9,600 W19,200 W
90 A1,080 W10,800 W21,600 W
100 A1,200 W12,000 W24,000 W
125 A1,500 W15,000 W30,000 W
150 A1,800 W18,000 W36,000 W
175 A2,100 W21,000 W42,000 W
200 A2,400 W24,000 W48,000 W

The formula behind every row

Each cell is one multiplication: W = A × V. Anything not on the chart takes five seconds: 37 A on a 240 V welder circuit is 37 × 240 = 8,880 W. The reverse — watts to amps — is just as short: A = W ÷ V. A 1,500 W space heater on 120 V draws 12.5 A; the same heater on 230 V mains draws 6.5 A. For AC circuits with motors or electronics, multiply by the power factor (typically 0.8–0.95): a 10 A, 120 V compressor at PF 0.8 delivers 960 W of real work, not the 1,200 W the chart shows. The calculator handles the PF and three-phase math for you.

Worked examples from the chart

  • Space heater on a 15 A outlet: the chart gives 1,800 W at 120 V — a 1,500 W heater fits with room to spare, and two of them (3,000 W) will trip the breaker.
  • Dryer on a 30 A, 240 V circuit: 7,200 W available, so a 5,600 W dryer is well within limits even after the 80% continuous-load rule.
  • 100 W load on a 12 V battery: the chart read in reverse — 100 ÷ 12 ≈ 8.3 A — explains why a car battery running an inverter drains fast: every 120 W of AC output pulls 10 A from the battery.
  • Inverter sizing: a 20 A, 120 V well pump needs 2,400 W of chart power, but the motor's starting surge can triple that — which is where a wattage sizing calculator earns its keep.

Three-phase values (quick correction)

The chart covers single-phase and DC circuits. For three-phase power — commercial panels, large pumps, workshop machinery — multiply the 240 V column value by 1.732 × PF. At PF 0.9, a 20 A three-phase circuit delivers 20 × 240 × 1.732 × 0.9 ≈ 7,482 W, versus 4,800 W single-phase. The calculator has a three-phase mode that applies the factor for you.

skip the table

Amps to Watts Calculator

Any amps, any volts, DC or three-phase, with an adjustable power factor. It also shows the NEC 80% continuous limit for the circuit you're checking.

Convert a value

Keep reading

New to the three units? Start with amps vs watts vs volts — the water analogy and the one formula behind the whole chart. Checking a real circuit before plugging in? The circuit capacity guide applies the NEC 80% rule breaker by breaker.

faq

Frequently Asked Questions

Four quick reads on the chart's most-looked-up values.

How do I convert 15 amps to watts?

Multiply amps by volts. 15 A on a standard 120 V outlet is 15 × 120 = 1,800 W; on a 240 V circuit it is 3,600 W; on a 12 V battery it is 180 W. The same amperage means different watts at different voltages, which is why the voltage column matters as much as the amp value.

How many watts is 30 amps at 240 volts?

7,200 W, from 30 × 240. That is the theoretical maximum; under the NEC 80% continuous-load rule a 30 A circuit should carry no more than 5,760 W for loads running three hours or more — which is why electric dryers are designed to draw well under the breaker rating.

Does power factor change the values in the chart?

Yes, for anything with a motor, compressor or electronic power supply. The chart assumes power factor 1.0 (exact for heaters, bulbs and batteries). At PF 0.8, real watts are 20% lower than the chart value: a 10 A, 120 V compressor is listed at 1,200 W but actually delivers about 960 W of work. Divide the chart number by the power factor to get volt-amps, which is what generators and inverters are sized on.

How many watts is 100 amps?

It depends on the voltage: 1,200 W on a 12 V battery bank, 12,000 W on a 120 V service, and 24,000 W on 240 V. A 100 A, 240 V residential service entrance therefore supports a theoretical 24,000 W across all circuits combined, before the 80% continuous-load rule brings the safe continuous figure to 19,200 W.