What a watt-hour actually measures

A watt is a rate: it says how fast energy is being used at this instant. A watt-hour is a quantity: it says how much energy was used in total. The difference is the same as between a car's speedometer and its odometer.

Multiply the rate by the time and you have the quantity:

watt-hours = watts × hours

That single line explains most power-station marketing. A 100 W television running for 7.5 hours uses 750 Wh. A 10 W phone charger uses the same 750 Wh over 75 hours. Same energy, radically different power. A station's watt-hour rating pays for the total; its watt rating decides whether a load can start at all.

Wh vs W vs Ah: the three units side by side

Batteries are sold in amp-hours, devices in watts, and power stations in watt-hours. They are all the same family of measurement — one is a rate, one is a quantity, one is charge.

Unit Measures Formula Example
W (watt)Rate of energy useW = V × AA 1,500 W heater draws 12.5 A at 120 V
Wh (watt-hour)Energy quantityWh = W × h1,500 W for 0.5 h = 750 Wh
Ah (amp-hour)ChargeAh = A × h100 Ah at 12 V = 1,200 Wh

The conversion between Ah and Wh needs the voltage, which is the step people skip. Wh = Ah × V. A 100 Ah battery at 12 V is 1,200 Wh; the same 100 Ah at 24 V is 2,400 Wh. Amp-hours alone cannot size a power station, because they say nothing about voltage.

How many watt-hours is a 12 V 100 Ah battery?

On paper, 1,200 Wh. In practice, less — first because the pack should not be drained flat, and second because the inverter loses energy on the way out. Here are the common battery sizes converted to usable energy at a 90% depth of discharge and 88% inverter efficiency:

Battery Nameplate Wh Usable at 90% DoD, 88% inverter
12 V 50 Ah600 Wh475 Wh
12 V 100 Ah1,200 Wh950 Wh
12 V 200 Ah2,400 Wh1,901 Wh
24 V 100 Ah2,400 Wh1,901 Wh

Usable = nameplate × 0.90 × 0.88 = nameplate × 0.792. A lead-acid pack uses a 50% depth of discharge instead, which cuts the same 1,200 Wh battery to 528 Wh.

The three losses between nameplate and outlet

"1,000 Wh" is measured at the cells with a slow, perfect discharge. Three things stand between that lab number and the energy your laptop receives:

  • Depth of discharge (DoD). The battery management system stops the pack before it is truly empty to protect its lifespan. LiFePO4 allows about 90%, NMC lithium about 85%, lead-acid about 50%.
  • Inverter efficiency. Turning DC battery power into 120 V AC wastes some as heat. Most stations publish 85–90%; the site's default is 88%.
  • Standby draw. An inverter that is switched on burns a few watts even with nothing plugged in — typically 5–15 W on larger units. Over a 20-hour run, 5 W is 100 Wh gone.
Chemistry Depth of discharge Inverter efficiency Usable from 1,000 Wh
LiFePO490%88%792 Wh
NMC lithium85%88%748 Wh
Lead-acid50%88%440 Wh

Two "1,000 Wh" boxes with different chemistry are therefore different products. The lead-acid one delivers barely more than half the runtime of the LiFePO4 one, and it weighs considerably more.

What capacity buys in real runtime

Run the usable figures against two everyday loads and the capacity ladder becomes concrete. Each row assumes the device runs alone, with the 5 W standby draw included:

Nameplate capacity Usable energy Laptop (50 W) Phone charger (10 W)
300 Wh238 Wh4 h 19 m15 h 50 m
500 Wh396 Wh7 h 12 m26 h 24 m
1,000 Wh792 Wh14 h 24 m52 h 48 m
2,000 Wh1,584 Wh28 h 48 m105 h 36 m
3,600 Wh2,851 Wh51 h 50 m190 h 05 m

The full runtime chart covers eight devices across the same five capacities, and the runtime calculator lets you tick your own combination.

Watt-hours, kilowatt-hours and what the grid charges

Your electricity bill is also denominated in energy, just in a bigger unit: 1 kWh = 1,000 Wh. A 1,000 Wh power station therefore holds exactly one kilowatt-hour.

At the site's 18.16¢/kWh reference rate, that kilowatt-hour costs about 18¢ from the wall. Charging the station is not free of losses — if the charger is 90% efficient, drawing 1.11 kWh costs about 20¢. Compare that with a gasoline generator at 5 kW and 75% load: 0.60 gal/h at 3.50 a gallon is 2.10 an hour for 3.75 kWh, or about 56¢/kWh. The battery is roughly a third of the fuel cost per unit of energy, before maintenance and noise.

Why two 1,000 Wh stations run different lengths

Two units with the same label can differ by 30% in delivered runtime. The variables, in order of impact:

  • Chemistry and depth of discharge — the 792 vs 440 Wh gap above.
  • Inverter efficiency — an 85% unit delivers 765 Wh where a 90% unit delivers 810 Wh from the same 90% DoD pack.
  • Standby draw — a 15 W inverter idles away 360 Wh in a day; a 5 W unit loses 120 Wh.
  • Temperature — a pack stored below freezing delivers noticeably less than its rating, and charging it cold can damage it.
  • Age — lithium packs are usually rated to 80% of original capacity after 3,000–5,000 full cycles, so a two-year-old station no longer matches its label.

The calculator lets you change chemistry, DoD, inverter efficiency and standby draw so the answer reflects the unit you actually own, not the brochure.

try it with your numbers

Portable Power Station Runtime Calculator

Set the capacity, chemistry and inverter efficiency, tick your devices, and watch the runtime update. It also runs backwards to size a station from the hours you need — nothing leaves your browser.

Open the calculator

faq

Frequently Asked Questions

The unit questions that come up before every power-station purchase.

What is the difference between a watt and a watt-hour?

A watt is a rate — how fast energy is used right now. A watt-hour is a quantity — one watt sustained for one hour. A 100 W TV draws 100 W at any instant and uses 750 Wh over seven and a half hours, while a 10 W phone charger uses the same 750 Wh over 75 hours.

How many watt-hours is a 12 V 100 Ah battery?

1,200 Wh on paper: 100 Ah × 12 V. Usable energy is lower because you cannot drain it flat and the inverter loses some in conversion. At a 90% depth of discharge and 88% inverter efficiency a lithium pack delivers 950 Wh; a lead-acid pack limited to 50% depth of discharge delivers 528 Wh.

Why does my 1,000 Wh power station not deliver 1,000 Wh?

Because nameplate capacity is measured at the cells, not at the outlet. The battery management system holds back about 10% to protect the pack, the inverter keeps roughly 88% of what it converts, and the station itself draws a few watts to stay on. 1,000 × 0.90 × 0.88 = 792 Wh, and the standby draw trims it further over a long run.

Is a watt-hour the same as a kilowatt-hour?

No, it is a thousandth of one: 1 kWh = 1,000 Wh. A 1,000 Wh power station holds exactly 1 kWh, which at the site's 18.16¢/kWh reference rate is about 18¢ of grid electricity — roughly 20¢ once charging losses are counted.