How to read the chart

Three numbers produce every figure in these tables, and product pages publish only the first:

  • Usable watt-hours = nameplate capacity × the depth of discharge the chemistry allows. The chart uses 85% for lithium, which is the figure most power-station makers use; LiFePO4 supports 90% and lead-acid or AGM 50%.
  • Draw at the battery = the machine's watts ÷ the path's efficiency, plus whatever the converter or inverter burns sitting idle. A 34 W machine is 34 W on a DC input, 40.1 W through a 12-to-24 V converter, and 46 W through an inverter.
  • Nights = usable watt-hours ÷ that draw ÷ hours slept, here eight.

The two tables are the same batteries with a different path. Read Table A if your machine takes 12 V DC directly — most travel units and many CPAP DC adapters do. Read Table B if you are plugging the machine's own wall brick into an AC outlet.

Table A: nights on a direct 12 V input

No converter, no inverter, no standby burn — the pack feeds the machine straight through. This is the best case, and it is the case a 12 V CPAP cable gives you.

Pack (Wh) Usable at 85% 10 W travel unit 22 W humidifier 34 W heated tube 55 W bi-level
9681.61.020.460.300.19
150127.51.590.720.470.29
3002553.191.450.940.58
5004255.312.411.560.97
1,00085010.634.833.131.93
1,5001,27515.947.244.692.90
2,4002,04025.5011.597.504.64
3,6003,06038.2517.3911.256.95

Figures are nights of eight hours' sleep on a lithium pack at 85% usable, warm, with no conversion loss. These are the same capacities the CPAP battery calculator offers as quick chips.

Table B: nights through an AC inverter

The same packs, with a pure-sine inverter in the middle at 85% efficiency and a 6 W no-load draw. That idle figure is what makes small packs collapse: 6 W on top of a 10 W machine is a 60% overhead before the conversion loss is counted.

Pack (Wh) Usable at 85% 10 W travel unit 22 W humidifier 34 W heated tube 55 W bi-level
9681.60.570.320.220.14
150127.50.900.500.350.23
3002551.791.000.690.45
5004252.991.671.160.75
1,0008505.983.332.311.50
1,5001,2758.975.003.462.25
2,4002,04014.368.005.543.61
3,6003,06021.5312.008.325.41

Each night here costs the pack 142.1 Wh at 10 W, 255.1 Wh at 22 W, 368.0 Wh at 34 W and 565.5 Wh at 55 W — the machine's own watt-hours plus the inverter's conversion loss and its 6 W idle burn.

Compare the 1,000 Wh row across both tables: 3.13 nights becomes 2.31, and 10.63 becomes 5.98. At 10 W the inverter costs you nearly half the pack; at 55 W it costs about a fifth. The smaller the machine, the more the path matters.

The chemistry column

Nameplate capacity is the least trustworthy number on a battery, and depth of discharge is the reason. The same 1,000 Wh box with a 34 W machine on DC:

Chemistry Usable share Usable Wh from 1,000 Nights at 34 W Nameplate for 3 nights
LiFePO490%9003.31907 Wh
Li-ion NMC / power bank85%8503.13960 Wh
Lead-acid or AGM50%5001.841,632 Wh

The AGM row is the one that surprises people. A 100 Ah AGM leisure battery in a van is 1,200 Wh on paper and 600 Wh in the world, because discharging lead-acid past half its capacity is how you kill it in a few dozen cycles. Lithium does not have that limit, which is the actual argument for buying it for a CPAP: not weight, but the fact that you can use the whole tank.

The cold column

A cold pack delivers less of its rated energy, and a CPAP in a cold room draws more. Both effects point the same way, so a winter figure is never a summer figure divided by one number. For a lithium pack, approximate capacity retention:

Ambient Capacity kept Nights at 34 W on DC Hours at 34 W on DC
Above 20 C / 68 F100%3.1325.0
Near 0 C / 32 Fabout 80%2.5020.0
−20 C / −4 Fabout 55%1.7213.8

LiFePO4 has a second cold problem the derate does not capture: it will not accept a charge below freezing, and forcing one damages the cells. A pack brought in from a cold car and put on a charger can refuse to fill even though it reads empty. Bring it inside, let it warm, then charge it.

When the battery is sold in amp-hours

Camper and marine batteries quote amp-hours, and the chart is in watt-hours. Multiply by the pack's voltage and the two are the same thing: 100 Ah at 12 V is 1,200 Wh, and 100 Ah at 24 V is 2,400 Wh.

12 V battery Nameplate Wh Nights at 34 W, lithium Nights at 34 W, AGM
30 Ah3601.130.66
50 Ah6001.881.10
100 Ah1,2003.752.21
150 Ah1,8005.633.31
200 Ah2,4007.504.41

A 40 Ah or 100 Ah LiFePO4 "slimline" is labelled at 12.8 V or 25.6 V nominal rather than 12 V, and its real figure is printed on the case — 40 Ah at 25.6 V is 1,024 Wh, not 480. Check the label before you divide.

The one formula behind every row

Nights = (nameplate Wh × usable share × cold factor) ÷ (watts ÷ path efficiency + path idle) ÷ hours slept
→ 1,000 Wh × 0.85 ÷ (34 ÷ 0.85 + 6) = 18.5 h = 2.3 nights through an inverter

Or run it backwards when you are shopping, which is the more useful direction. Three nights at 34 W is 816 Wh delivered, and 816 ÷ 0.85 = 960 Wh of li-ion nameplate. Then add the path: 18% on top for a DC-DC converter, 35% for an AC inverter — 960 Wh becomes 1,133 Wh or 1,296 Wh.

What these rows mean for a purchase

Situation Machine Wh needed per night Nights LiFePO4 nameplate AGM nameplate
Overnight flight, carry-on10 W travel unit80189 Wh160 Wh
Weekend trip10 W travel unit802178 Wh320 Wh
One night at home, heated tube34 W2721302 Wh544 Wh
Blackout kit34 W2723907 Wh1,632 Wh
Week off-grid34 W27272,116 Wh3,808 Wh
Heated bi-level, one night55 W4401489 Wh880 Wh

Two caveats the table cannot carry. The first row and a weekend trip have to fit the airline rules: 160 Wh is the ceiling for a carry-on lithium battery without the airline's agreement, and carriers want 150% of the flight's expected consumption — which is why the 96 Wh bank is the standard answer for flying and 300 Wh packs are checked-baggage territory at best. The second: a week off-grid at 2,116 Wh is a heavy, expensive battery, while the same week with a 200 W panel and a sunny day is a 500 Wh pack. Recharging changes the size you buy, and how to run a CPAP on battery works that through.

Where the watt figures themselves come from — and why the 90 W on your power brick is not your consumption — is covered in how many watts a CPAP uses.

try it with your numbers

CPAP Battery Runtime Calculator

Every row in this chart is one setting in the calculator. Choose your machine, your pack and the path between them and get nights, the size to buy, and the FAA check on the same screen.

Open the calculator

faq

Frequently Asked Questions

The size questions people ask standing in front of a battery shelf.

What size battery do I need for a CPAP?

Nights, watts and hours slept, divided by what the pack can actually give. A 34 W heated machine takes 272 Wh out of the battery each night, so three nights is 816 Wh delivered. Divide by the usable share — 0.90 for LiFePO4, 0.85 for li-ion, 0.50 for AGM — and the nameplate you need is 907 Wh, 960 Wh or 1,632 Wh. Add 18% on top for a DC-DC converter, or 35% for an AC inverter.

How many watt-hours does a CPAP need for one night?

One eight-hour night is 56 Wh with nothing heated, 176 Wh with the humidifier on, 272 Wh with a heated tube and 352 Wh for a heated bi-level. Those are the watts drawn by the machine; the pack has to be bigger, because a 272 Wh night needs 302 Wh of LiFePO4 or 320 Wh of li-ion nameplate before any converter loss is counted.

Can a 100 Ah battery run a CPAP?

Yes, for several nights — if it is a 12 V battery and you respect its depth of discharge. 100 Ah at 12 V is 1,200 Wh, so a 34 W machine on a DC input gets 3.7 nights from a lithium pack at 85% usable and 2.2 nights from an AGM battery at 50%. Put an AC inverter in the middle and the same lithium pack gives 2.8 nights.

Is a power bank enough for CPAP travel?

For one night of a travel unit, yes. A 96 Wh airline-legal bank holds 81.6 Wh usable, which is 8.2 hours at 10 W — a full night — and 2.4 hours at 34 W, which is not. Stacking two 96 Wh banks still leaves a heated machine short of a night, because the arithmetic needed is 272 Wh, not 192 Wh.

How does cold change the chart?

Every figure drops by the same factor. A pack at 0 C gives roughly 80% of its rated energy and one at −20 C about 55%, so the 3.1 nights a 1,000 Wh li-ion bank provides at 34 W becomes 2.5 nights in a 0 C garage and 1.7 nights parked outside in winter. LiFePO4 is worse than the derate suggests: it will not accept a charge below freezing, so a cold tent can leave a pack that reads full unable to refill.